The Tasso+ is a sterile, single-use blood collection device. It adheres to the skin, creates a small puncture, and uses a gentle vacuum to draw capillary blood into a collection tube. Once the tube is full or collection time ends, the device is removed, and the tube is capped for transport. This article walks you through every step.
Important: Activate your kit before you collect. The lab cannot process an unactivated sample.
Before you start
Wash and dry your hands. Set out all kit contents on a clean surface.
The device will be placed on the upper arm - for best results, remove any excess hair.
Take out all items from the kit. Remove the device from the tray. Unwrap the bandage and gauze and set aside.

Twist off the cap from the tube. Set aside the DOB sticker label for later use.
Press the tube into the device until snug. Be mindful of the sticker and position the tube so you can watch it fill.
Clean the area with an alcohol pad and allow to dry. Then, use the alcohol pad to clean the heat pack.

Follow the heat pack instructions to activate. If a heat pack was not included in the kit, you can use your hand.
Rub the heat pack or your hand up and down your shoulder for four minutes. This will increase blood flow.
Remove the clear cover from the red button on the Tasso+ device.

Note: If your upper arm is very hairy, shave the collection spot before you begin. The device must form a firm seal against skin to create the vacuum that draws blood out. Hair prevents a good seal.
Placing the device and collection
Peel the tab away from the device and stick the device to your upper arm, hanging your arm straight down at your side. Remain seated during collection to reduce the risk of dizziness or fainting.
Press the button all the way down ONCE and release. Set a timer for 5 minutes and watch the tube fill, using a mirror if necessary.
Note: Press firmly - some resistance is normal and you may hear a faint click.
Blood may not appear for the first 1-2 minutes. Remove the device at 5 minutes total or as soon as the blood reaches the top fill line.

Important: Keep your arm hanging straight down at your side during the entire collection. Resting your arm on a table or armrest reduces blood flow to the site and can cause the blood to clot before the tube fills.
After collection
With the gauze and bandage ready, peel the device off from one side.
Press gauze on the puncture site and apply the bandage vertically with light pressure.
Remove the tube from the device with a slight twist and pull down.
Snap the cap fully onto the tube until it clicks. Ensure it is secure.

Gently invert the tube 8-10 times. Do NOT shake the tube.
Write your Date of Birth on the sample tube label. Failure to do this will result in your sample being rejected from the lab.
Fill out the included form with your Full Name, Date of Collection, DOB, and signature. Follow the provided shipping instructions to mail your sample.

Note: Any missing information will result in sample rejection.
Need more help?
If the device did not stick securely, the tube did not fill, or anything looks different from what is described here, contact our support team through chat.